Product Description
|
Technical data Marcom 0.35T |
Sternmed Open MRI |
|
Magnet |
|
|
Operating Field Strength |
0.35 Tesla 3500 Gauss |
|
Magnet Type |
Full open C-shaped, 2-column |
|
Magnetic material |
Permanent Nd-Fe-B magnet |
|
Dimension |
1970mm*1320mm*1820mm |
|
Net Weight |
17,500KGS |
|
Homogeneity |
(400mm DSV) ≤ 2.0ppm (Vrms) (200mm DSV) ≤ ±1ppm (FWHH) |
|
Shimming |
Passive shimming or active shimming |
|
Patient aperture |
400mm |
|
Gradient System |
|
|
Gradient strength |
max. 25mT/m (Gx/Gy/Gz) |
|
Slew rate |
64mT/M/ms (Gx/Gy/Gz) |
|
Gradient linearity |
<5%(400mm×400mm×380mm) |
|
RF System |
|
|
Central frequency |
DC ~ 400MHz |
|
Spectrometer |
Digital (Four channels) |
|
Transmitting coil |
Flat planar coil |
|
Receiving coils |
Phase array coil (Neck coil, Head coil, Large body coil, Small body coil |
|
Optional coils |
spine coil, breast coil, ankle coil, etc. |
|
Max. receiver bandwidth |
1.25Mhz |
|
Power of transmitter amplifier |
6KW |
|
Computer System |
|
|
Operating system |
Windows2000/NT/XP |
|
CPU |
2.8GHz(Dual Core Processor) |
|
Hard disk |
≥250GB |
|
RAM |
2048MB (1GB) |
|
Display Device |
≥22’’ TFT |
|
Network & laser printer |
DICOM3.0 |
|
interface |
|
|
Pulse Sequence |
Standard IR |
|
Spin Echo ( SE 2D/3D) |
|
|
Multi-slice multi-echo (MSME) |
|
|
Gradient Echo (GRE 2D/3D) |
|
|
Steady state process gradient echo( SSPGRE) |
|
|
Fast spin echo (FSE) |
|
|
Single shot fast spin echo(SSFSE) |
|
|
Multi shot fast spin echo (MSFSE) |
|
|
Inversion recovery (IR) |
|
|
Short time inversion recovery (STIR) |
|
|
Inversion recovery fast spin echo (IRFSE) |
|
|
Fluid attenuated inversion recovery ( FLAIR) |
|
|
MRM ,MRU ,MRCP |
|
|
TOF 2D/3D MRA |
|
|
|
Diffusion weighted imaging (DWI) |
|
Echo planar imaging(EPI) |
|
|
Scanning Parameter |
|
|
Acquisition matrix |
64/128/256/512 |
|
Resolution |
1mm(head 24cm FOV 256X256) 1.5MM(body 30cm FOV 256X256) 0.5mm(head 24cm FOV 512X512) 0.75mm( body 30cm FOV 512X512) |
|
Maximum display matrix |
1024×1024 |
|
FOV |
20 ~ 400mm |
|
Slide thickness |
(2D)Min.1mm(1mm increment),(3D)Min. 0.5mm |
|
Slide Orientation |
Sagittal, coronal, transversal, any angle any oblique |
|
Image Type |
|
|
Image Type |
T1 Weighted imaging , T2 weighted imaging ,T2* weighted imaging , proton density imaging;Water Suppressed Image, Fat Suppressed Image, MRM, MRU,MRCP; Magnetic Resonance angiography (MRA), Diffusion Weighted Imaging (DWI) |
|
Patient Table |
|
|
Patient Table |
Max. Patient load about 240kg |
|
|
Available with laser light localizer for patient positioning |
|
|
Longitudinal travel range: ≥1650mm |
|
|
Equipped with intercommunication between patient and operator |
|
Power Supply |
|
|
Power Supply |
3N—380V 50Hz 15KVA |
|
Typical Layout |
|
|
Magnet Room |
About 30m2(5m×6m); |
|
Equipment Room |
About 9m2(3m×3m); |
|
Control Room |
About 9m2(3m×3m); |
|
Total MRI-System area |
About 48m2. |

![marcom-0-35t[1] marcom-0-35t[1]](https://www.bigseamedical.com/wp-content/uploads/2015/06/marcom-0-35t1.jpg)