  • 7” high resolution color TFT screen
  • 5 or 7-channelwaveform display with trend coexistence, switchable to observing screen
  • Monitoring standard parameters of ECG,Spo2, RESP,NIBP,TEMP & PR
  • Optimized modes for adult, pediatric & neonate
  • Automatic analysis of 20 arrhythmia waveforms
  •  S-T segment with automatic & manual analysis
  • DigitalSpo2 technology with anti-motion & anti-low infusion
  • Trend data analysis for 6/24/120/480 hours
  • Store & review 800 groups of NIBP list data & 24-hour ECG waveforms
  •  Audio and Visual alarms with 3-level classification
  • Protection against interference from defibrillator & electrosurgical unit
  • Removable rechargeable battery
  • Network capability (optional)


Brand: .

Product Description

Technical Specification MACS 10

Sternmed Patient Monitor

ECG

ECG Amplifier Bandwidth

Monitoring mode:O.5-40Hz

Diagnosis mode:0.05-75Hz

CMRR

>89dB

Heart Rate

Range

20-300bpm

Accuracy

+1% or +2bpm, whichever is greater

ECG Gain

1/2

5mm/mV@+5%

1

10mm/mV@+5%

2

20mm/mV@+5%

ECG Sweeping Speed

12.5mm/s, 25mm/s, 50mm/s@+10%

NIBP

Measurement Method

Intelligent oscillometric method

Parameters

Systolic, diastolic & mean pressure

Working Modes

Manual, automatic & STAT (5 minutes)

Pneumatic Pressure Range

0-300 mmHg

Cuff Type

Adult (standard)

Child/neonate (standard)

Average Measurement Time

<90sec

Inflation Time

<10sec (typical adult cuff)

Deflation Time

<2sec (typical adult cuff)

Monitoring Range

Adult

Systolic 40-255mmHg

Mean 20-215mmHg

Diastolic 10-195mmHg

Child

Systolic 40-200mmHg

Mean 20-165mmHg

Diastolic 10-150mmHg

Neonate

Systolic 40-135mmHg

Mean 20-110mmHg

Diastolic 10-95mmHg

Overpressure Protection Limit

Adult

300mmHg

Child

240mmHg

Neonate

150mmHg

NIBP Accuracy

Maximum mean error +5 mmHg

Maximum standard deviation 8 mmHg

RESP

Measurement Method

Thoracic Impedance

Measurement Range

0-120bpm

Accuracy

+5% or +2bom, whichever is greater

Alarm Limit Range

0-120bpm

TEMP

Range

25.0-45.0·C

Accuracy

+0.2°C

Responding Time

< 150sec

SpO2

Transducer

Dual-wavelength LED

SpO2 Measuring Range

35-100%

SpO2 Measuring Range

+3% (50-100%) (RMS of difference)

Low Perfusion Capability

0.4-5%

Pulse rate Measuring Range

30bpm-240bpm

Accuracy of Pulse Rate

+2% or +2bpm, whichever is greater

General Specifications

Power Supply

100-240VAC, 50/80Hz

Display Mode

7 inches TFT color LCD

Alarming Mode

Audible & visible alarm

Communication

Ethernet port

Battery

Rechargeable lithium battery

Classification

Safety Standard

IEC 60601-1

Type of Protection Against Electric Shock

Type BF, CF applied parts

Degree of Protection Against Electric Shock

Class I equipment

Electro-Magnetic Compatibility

Group I, Class B